For any machine which has undergone testing, the Tests log screen – under the “Tests” tab – shows a list of tests that have been run for that machine, along with a timestamp and result. You can view the detailed logs for each test script from this tab.

By default, every MAAS machine is tested with the smartctl-validate script, which is a script prepared by Canonical using the smartmontools kit. This is a disk integrity test. Typical output includes the following:

INFO: Verifying SMART support for the following drive: /dev/sda
INFO: Running command: sudo -n smartctl --all /dev/sda
INFO: SMART support is available; continuing...
INFO: Verifying SMART data on /dev/sda
INFO: Running command: sudo -n smartctl --xall /dev/sda
SUCCESS: SMART validation has PASSED for: /dev/sda
--------------------------------------------------------------------------------
smartctl 6.6 2016-05-31 r4324 [x86_64-linux-4.15.0-115-generic] (local build)
Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Device Model:     QEMU HARDDISK
Serial Number:    QM00001
Firmware Version: 2.5+
User Capacity:    5,368,709,120 bytes [5.36 GB]
Sector Size:      512 bytes logical/physical
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   ATA/ATAPI-7, ATA/ATAPI-5 published, ANSI NCITS 340-2000
Local Time is:    Wed Sep  2 22:29:12 2020 UTC
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is:   Unavailable
APM feature is:   Unavailable
Rd look-ahead is: Unavailable
Write cache is:   Enabled
ATA Security is:  Unavailable
Wt Cache Reorder: Unavailable

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x82) Offline data collection activity
                    was completed without error.
                    Auto Offline Data Collection: Enabled.
Self-test execution status:      (   0) The previous self-test routine completed
                    without error or no self-test has ever 
                    been run.
Total time to complete Offline 
data collection:        (  288) seconds.
Offline data collection
capabilities:            (0x19) SMART execute Offline immediate.
                    No Auto Offline data collection support.
                    Suspend Offline collection upon new
                    command.
                    Offline surface scan supported.
                    Self-test supported.
                    No Conveyance Self-test supported.
                    No Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                    power-saving mode.
                    Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                    No General Purpose Logging support.
Short self-test routine 
recommended polling time:    (   2) minutes.
Extended self-test routine
recommended polling time:    (  54) minutes.

SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAGS    VALUE WORST THRESH FAIL RAW_VALUE
  1 Raw_Read_Error_Rate     PO----   100   100   006    -    0
  3 Spin_Up_Time            PO----   100   100   000    -    16
  4 Start_Stop_Count        -O----   100   100   020    -    100
  5 Reallocated_Sector_Ct   PO----   100   100   036    -    0
  9 Power_On_Hours          PO----   100   100   000    -    1
 12 Power_Cycle_Count       PO----   100   100   000    -    0
190 Airflow_Temperature_Cel PO----   069   069   050    -    31 (Min/Max 31/31)
                            ||||||_ K auto-keep
                            |||||__ C event count
                            ||||___ R error rate
                            |||____ S speed/performance
                            ||_____ O updated online
                            |______ P prefailure warning

Read SMART Log Directory failed: scsi error badly formed scsi parameters

General Purpose Log Directory not supported

SMART Extended Comprehensive Error Log (GP Log 0x03) not supported

SMART Error Log Version: 1
No Errors Logged

SMART Extended Self-test Log (GP Log 0x07) not supported

SMART Self-test log structure revision number 1
No self-tests have been logged.  [To run self-tests, use: smartctl -t]

Selective Self-tests/Logging not supported

SCT Commands not supported

Device Statistics (GP/SMART Log 0x04) not supported